Philips UV-C Disinfection Upper Air Wall Mounted

Philips UV-C Disinfection Upper Air Wall Mounted

Breathe healthy air

Philips T5 TUV 25W lamp included
Shortwave UV radiation peak at 253.7 nm (UV-C)
Louvres and reflector control the distribution of UV-C at the device level and above, where people are not usually present
Wall mounted installation
Complies with IEC 62471 standard for photobiological safety

Product Info

As part of the Philips UV-C disinfection upper air device series, Philips UV-C disinfection upper air wall mounted is designed to be installed on walls for the disinfection of air in a wide range of applications. Optimized for low ceiling heights, the UV-C rays are distributed at device level and above. The beam of UV-C rays is controlled by specific reflectors and the louvre design. This allows for the disinfection of the air in a space, while ensuring that day-to-day business activities can continue underneath the area where the device is active.

Benefits

Our Philips UV-C disinfection upper air wall mount luminaires inactivated 99.99% of SARS-COV-2, the virus responsible for the COVID-19 disease, in the air of a room within 10 minutes. At 20 minutes, the virus was below detectable levels. [1]
Swift disinfection effect, with 83.6% reduction of SARS-CoV-2, the virus that causes the COVID-19 disease, achieved in a room within 2 minutes. [1]
Allows quiet disinfection of air while business activity continues underneath the device’s level
Uses Philips UV-C lamps and drivers
Environmentally friendly - no ozone emissions during or after use

Applications

Office
Retail
Food outlets
Hospitality
Schools
Banking
Washrooms

Warning & Safety

DANGER: Risk Group 3 UV product. Like any disinfection system, UV-C lamps and devices must be installed and used in the correct way. Direct exposure to UV-C can be dangerous and result in a sunburn-like reaction to the skin and serious damage to the cornea. As UV-C is invisible to the eye, the UV-C upper air device must be installed together with adequate safeguards to ensure that the UV-C upper air device can be operated in a safe way. The UV-C upper air device are only to be used as components in a system that consists of adequate safety safeguards such as, but not limited to, those indicated in the mounting instructions and/or user manuals. Direct exposure to UV-C is dangerous. Philips UV-C luminaires systems must only be sold through qualified partners and installed by professionals according to our stringent safety and legal requirements. Our UV-C products are not meant to be used in applications or activities which may cause and/or lead to death, personal injury and/or damage to the environment.
[1] According to results obtained from a laboratory test conducted by Innovative Bioanalysis, a CAP, CLIA, AABB Certified Safety Reference Laboratory, in a room with sufficient air circulation. For more information, please refer to the test report available in the "related tools" part of this webpage.

General information

Number of light sources: 1 pc

Number of gear units: 1 unit

Gear: HF-S [ HF Selectalume]

Optic type: Lamellae louver

Connection: Push-in connector 3-pole

Protection class IEC: Safety class I

Glow-wire test: Temperature 650 °C, duration 30 s

CE mark: CE mark

Warranty period: 1 years

Number of products on MCB of 16 A type B: 28

Photobiological risk: Photobiological risk group 3 @ 200mm to EN62471

EU RoHS compliant: Yes

Product family code: WL345W [ PHILIPS UV-C DISINFECTION UPPER AIR]

Operating and electrical

Input Voltage: 230 V

Input Frequency: 50 Hz

Inrush current: 18 A

Inrush time: 0.35 ms

Power Factor (Min): 0.98

Controls and dimming

Dimmable: No

Mechanical and housing

Housing Material: Aluminum

Reflector material: Aluminum

Optic material: Aluminum

Mounting device: Wall-mounting bracket

Overall length: 553 mm

Overall width: 185 mm

Overall height: 140 mm

Color: White and black

Dimensions (Height x Width x Depth): 140 x 185 x 553 mm

Approval and application

Ingress protection code: IP20 [ Finger-protected]

Mech. impact protection code: IK02 [ 0.2 J standard]

UV

UV-C radiation: 0.375 W

UV-C irradiance defined at 2m: 356 mW/m²

UV-C irradiance defined at 0.2m: 4266 mW/m²

Initial performance (IEC compliant)

Initial input power: 29.6 W

Power consumption tolerance: +/-10%

Application conditions

Ambient temperature range: +10 to +40 °C

Performance ambient temperature Tq: 25 °C

Maximum dim level: Not applicable

Suitable for random switching: No

Product data

Full product code: 871869690445900

Order product name: WL345W 1xTUV T5 25W HFS

EAN/UPC – Product: 8718696904459

Order code: 919206000011

Numerator – Quantity Per Pack: 1

Numerator – Packs per outer box: 1

Material Nr. (12NC): 919206000011

Net Weight (Piece): 6.290 kg

Product Enquiry